APsystems DS3 Series
From the datasheet to the roof, and from the roof to the utility.
- 27 lessons
- 7 h 40 min
- 7 modules
Lesson 0.1How the DS3 Series works and what one module per input changesfull length, no account needed
What you will be able to do
- Choose the module by its cold voltage
The open-circuit voltage of the module, corrected to the lowest expected temperature at the site, against the 60 V maximum input of every DS3 model. Never the catalog value at 77 °F (25 °C).
SourceDS3 Series datasheet (USA/Canada), Rev2.3, p. 2 and p. 3; DS3 Series user manual (North America), REV2.3, p. 21
- Size the branch by the NEC, for the voltage you measured
Measure the service first: 240 V or 208 V between the two lines. Then 125 % of the continuous output current and the breaker limit by wire size: 20 A on 12 AWG copper, 30 A on 10 AWG copper. The datasheet lists 8 DS3-S at 208 V on a 30 A breaker; the code count gives 7, and the lesson shows why.
SourceDS3 Series datasheet (USA/Canada), Rev2.3, p. 2; NEC 2023
- Connect one module per input, in the order the manual sets
Both leads of one module on the same input, never split. AC first, with its ground, then DC: ten short green blinks within 10 seconds show the unit started.
SourceDS3 Series user manual (North America), REV2.3, p. 3 and p. 14
- Ground and bond the system
The three grounding paths in the manual: the ground conductor in the trunk cable, the grounding washer on grounded racking, or an external wire on the lug. The racking is grounded per local code.
SourceDS3 Series user manual (North America), REV2.3, p. 11 and p. 12
- Commission: ECU, EMA Manager and the grid profile
Install the ECU, register the system in EMA Manager and select the grid profile your utility requires. With the wrong profile, the micros may not start or may not produce as they should.
SourceEMA Manager app user manual, p. 64; ECU-R install and user manual, REV1.0, p. 13
- Read the LED and tell communication from production
Ten short green blinks at startup. Slow green: producing and communicating with the ECU. Fast green: producing, but no contact with the ECU for over 60 minutes. Solid red: a ground fault on the DC side.
SourceDS3 Series user manual (North America), REV2.3, p. 18
- Explain the warranty to the homeowner
25 years for the DS3 Series, from registration in EMA or 12 months after shipment, whichever comes first, as long as the ECU keeps the system connected to the internet. Without that connection, a 2-year legal warranty from shipment. The ECU goes online within 45 days after the system gets its operation permit, and stays online.
SourceUS limited warranty, L5.2US, p. 1 and p. 3
The lessons
27 lessons in 7 modules, 7 h 40 min in total.
M0Before the job5 lessons · 1 h 19 min
- 0.1How the DS3 Series works and what one module per input changesfree preview14:39
- 0.2The DS3 Series documentation and what each document answers12:10
- 0.3U.S. compliance: the series listing and what the certificate proves16:07
- 0.4Choosing the module: cold voltage, current and the plus sign14:20
- 0.5Who can install, PPE, tools and what the manufacturer supplies21:45
M1Mechanical installation3 lessons · 44 min
M2DC side2 lessons · 33 min
M3AC side4 lessons · 1 h 22 min
M4Communication and commissioning5 lessons · 1 h 33 min
M5Operation and monitoring3 lessons · 53 min
M6Troubleshooting and warranty5 lessons · 1 h 17 min
- 6.1LED, communication and production: the two failure trees14:24
- 6.2Field diagnosis: signal, communication, voltage and frequency16:46
- 6.3Field diagnosis: shade, grid trips, the solid red and the swap17:56
- 6.4The U.S. limited warranty, word for word12:45
- 6.5The RMA in the U.S.: from the support case to the Truck Roll14:55
Lesson 0.1 up close
How the DS3 Series works and what one module per input changes
Chapters
- Intro0:00
- 1What the microinverter does1:14
- 2Two modules, two inputs2:17
- 3The datasheet in six lines3:35
- 4Efficiency and night consumption7:04
- 5The four models of the series7:53
- 6Twenty-five years, with a condition9:44
- 7Not a hybrid11:04
- 8The unit of the document11:45
- 9The common mistake12:44
- 10Quick check13:09
- 11Checklist and next lesson13:34
What comes with it
- The document page on screen
Every number said in the lesson has a visible source: user manual, quick guide, datasheet, limited warranty or electrical code.
- Materials for the roof
6 pieces per lesson: summary, job checklist, equipment sheet, exercise, glossary and transcript.
- Questions during the lesson
Quick questions inside the video and a quiz at the end of each lesson.
- Daily review
5 minutes a day on the items you missed, at growing intervals. Coming back is what makes it stick.
- Job site mode
On the roof, the lesson checklist in full screen, big buttons, no video and no distractions.
- Verifiable certificate
Pass the final exam and get a certificate of completion with a public verification code that anyone can check online.
CourseAPsystems DS3 Series Microinverters
Who it is for
This is for you
- You are an electrician or solar installer working with the APsystems DS3 Series in the U.S.
- You lose time on the ECU, EMA Manager, the grid profile or callbacks.
- You want every number backed by the datasheet, the manual or the NEC, with the source on screen.
- You lead a crew and need everyone to install the same way.
This is not for you
- You install the 120 V DS3-LV or another microinverter. This course covers the DS3 Series at 208 V and 240 V.
- You need a license. This course does not grant one: licenses come from state and local law.
- You are looking for the APsystems Academy course. APsystems requires its free ECU/EMA course before your first EMA installer account, and this independent course does not replace it.
- You need OSHA training. The course covers safety basics; it does not replace OSHA training or your employer’s written procedures.
Questions about this course
Is this an APsystems course?
No. It is an independent online course from Microinverter Academy, with no ties to APsystems. It is built on the documents APsystems publishes for the U.S., shown on screen with the page.
Which models does it cover?
The DS3 Series at 208 V and 240 V: the 880 VA DS3 at the center, with the DS3-S, DS3-L and DS3-H wherever their numbers change. The 120 V DS3-LV is not part of this course.
Which NEC edition does it use?
The 2023 edition is the base, and each lesson says which edition it shows. Your AHJ decides which edition and which local amendments apply to your permit.
What does it take to complete the course?
Watch each of the 27 lessons to the end and pass its quiz. That opens the final exam: 34 questions in 51 minutes, one attempt per day, and you pass with 24 correct answers (70%). Pass it and you get the certificate of completion.
What do I receive at the end?
A certificate of completion with a verification code: it says you completed the course and passed the final exam. It does not grant a license, and APsystems does not issue it.
How long do I have access?
12 months from the purchase. If the manufacturer documentation or the electrical code changes, we update the lesson.
How do I pay?
A one-time payment of $49 USD, by Visa or Mastercard, on Stripe's secure page. No subscription.
What if the course is not for me?
You have 7 days to cancel, counted from the day after your purchase. The button is in your account, we do not ask why, and you get a full refund. When you cancel, your access ends.
The full course for the DS3 Series
27 lessons in the order of the job, job site materials, a final exam and a certificate of completion with a public verification code.
12 months of access7 days to cancelOne-time payment