The RMA in the U.S.: from the support case to the Truck Roll
Bad micro or bad module, the support case with the unit still installed, the U.S. RMA process, the Truck Roll step by step, the transfer to a new owner, and the end of the course.
What to keep from the last lesson of the course. Page numbers in the sources are the PDF pages of each document.
What this lesson solves
- Before the case, rule out on site the loose connection, the polarity and the module: a DC voltage one third lower than the other modules points to the module's junction box.
- Support first, with the unit still installed: model and serial number, a detailed description of the defect and the shipping address.
- No swap from stock before the RMA: APsystems provides no new replacement to an installer who swaps from stock at their own discretion.
- Truck Roll reimburses part of the labor under its conditions: active warranty, remote diagnosis and RMA before the swap, install within 3 years, request within three months of the RMA.
- A sold house: the Warranty Transfer Form within 30 days of the ownership transfer, with the ECU ID, by e-mail to the installer and to APsystems.
The numbers in this lesson, with sources
| What | Value | Fact |
|---|---|---|
| Truck Roll: inverter installation date | within 3 years of the claim date | 14.36 |
| Truck Roll: request | within three months of the RMA issuance | 14.36 |
| Truck Roll: in effect from | April 1, 2025 | 14.35 |
Each value comes from the course fact base, with the document page or the code section on record.
Chapters
- Intro0:00
- 1Bad micro or bad module1:17
- 2The support case and the RMA3:19
- 3Truck Roll, step by step8:12
- 4The warranty transfer10:46
- 5The common mistake11:55
- 6Quick check12:39
- 7Checklist and the end of the course13:06
Preview transcript
808 wordsThis is the text of the open part of this lesson. The full transcript comes with the course, along with the job site materials.
Intro
0:00The micro failed. The crew swapped it from the truck stock on Friday, and called support on Monday. No new unit from APsystems for that one, and no Truck Roll. On this path, the RMA comes before the swap. Hi, I'm Sol. This is lesson six point five, the last one of the course. And I'm Helios. Today I bring the support case, the replacement, and the Truck Roll paperwork. Today's documents: the U.S. RMA process, the Truck Roll policy, and the warranty transfer form. Lesson six point four read the warranty. Today it gets used. By the end of this lesson, you'll tell a bad micro from a bad module, and open a complete support case. And I'll file the Truck Roll on time, and I'll know what the buyer of a house needs for the warranty. And where do I start, with the homeowner waiting? With the defect. Then the case and the RMA, then the Truck Roll. And at the end, the transfer to a new owner, and the close of the course.
Bad micro or bad module
1:17Chapter one. Before the case, tell a bad micro from a bad module. Troubleshooting guide, page twenty: no power, some inverters, permanently. First, the DC and AC connections, checked thoroughly, opened only with the branch locked and tagged open. The guide lists the loose connection on that page. And before any connector opens, the absence of voltage on the branch is verified, backfeed included. Then the module. In the module details, check the DC voltage: too low, and the micro doesn't start. The operating range of the input is twenty-six to sixty volts. Below twenty-six, it doesn't start. And with the DC voltage one third lower than the other modules, the guide points to the module's junction box. And it says so plainly: that module needs to be replaced. Our reading: most modules have three bypass diodes, each across a third of the cells. A shorted one takes about a third of the voltage. To confirm, the inoperable microinverter sheet, step eleven: swap the DC leads with a known good, adjacent module. Then check the EMA again. It can take up to thirty minutes. If the problem moves to the other module, the module is at fault. If it stays, it's the micro. And that swap is done with the branch breaker off, locked and tagged, and no load on the DC. Same rule as always. Page nineteen, when only one channel doesn't produce: polarity reversed in DC extensions, twisted pairs, or crossed connections. Positive and negative of the same module, on different micros. That isn't a micro failure either. And everything I measured and ruled out goes in the case: voltages, photos, and dated screenshots.
The support case and the RMA
3:19Chapter two. The warranty, page two: the warranty right holder must strictly follow the RMA process. The one for the U.S.: the RMA process, United States. It's the one the U.S. warranty page links to. First step: contact an APsystems technical support representative while the product is still installed in its original location. Still installed. So the unit stays on the roof until I call. Right. The page gives the reason: many problems can be solved in the field. If that doesn't solve it, and APsystems finds the defect covered: repair or replace free of charge, or a refund. Once a replacement is decided, support needs three things. One: the model and serial number of the defective product. Two: a detailed description of the defect. Three: the shipping address for the replacement. And what do I bring to the case, besides those three? The warranty folder. The invoice from an authorized seller, and the installation map with the serial labels. The dates of the AHJ's final inspection, the written PTO and energizing, for the forty-five days. And dated EMA screenshots or exports. Photos of the LED and of the defect, and the measurements taken. And later, the case and RMA numbers, with their dates. The RMA process itself asks for detailed records. Who you call: APsystems U.S.A., in Austin, Texas. The troubleshooting guide, page thirty-one, has the phone and the e-mail. And the U.S. support page has a form. It asks if you're a professional installer or a homeowner, and for the ECU UID. And it tells the system owner: reach out to your original installer first. That's me. The RMA process recommends licensed and certified professionals for troubleshooting and RMAs. Support diagnoses remotely, from the system's data in the EMA. You register that system from your installer account, after the APsystems Academy course. And this course doesn't grant a license. Check your state and your AHJ. Page one again: APsystems ships the replacement by standard ground shipping, to the distributor, the installer, or the end user, at its discretion. It pays that shipment, not import duties or taxes. Expedited shipping is billed to the customer.
Job site materials in every lesson, questions inside the video, spaced review, a final exam and a certificate of completion with a public verification code. 7 days to cancel, with a full refund.