The trunk cable, connectors and the end cap
The three-conductor trunk cable, the colors of the U.S. documents, single-phase or three-phase, the click, the unlock tool and the torque that closes the end.
Every page cited is the page of the document's PDF file, not always the number printed on the page.
What this lesson solves
- The manual's "AC Y3 Bus cable" is the trunk cable: L1, L2 and PE, no neutral, with the micros in parallel.
- The DS3 takes the single-phase Y bus cable, with a green core; the three-phase one, with a blue core, is for the QT2.
- Every connector until the click; open them only with the mandatory unlock tool.
- End cap: strip 25 mm to 30 mm, seal, and the nut at 4 to 5 N·m until the latch meets the base.
- The trunk's working current, 28 A on 12 AWG and 35 A on 10 AWG, is one of the three branch limits: lesson 3.2.
The numbers in this lesson, with sources
| What | Value | Fact |
|---|---|---|
| Working current, 12 AWG and 10 AWG trunk | 28 A and 35 A | 8.4, 8.5 |
| Connector spacing, 12 AWG and 10 AWG | 2150 mm and 2400 mm | 8.4, 8.5 |
| End cap: jacket stripped | 25 mm to 30 mm (about 1.0 in to 1.2 in) | 8.10 |
| End cap: nut torque | 4 to 5 N·m (about 35 to 44 lbf·in) | 8.9 |
Each value comes from the course fact base, with the document page or the code section on record.
Chapters
- Intro0:00
- 1What the trunk cable does1:23
- 2The colors and the connector face5:00
- 3Single-phase or three-phase7:05
- 4The click, the tool and the cap8:23
- 5The end cap, step by step10:17
- 6Closing or extending the line12:14
- 7The cable's path14:34
- 8The common mistake17:06
- 9Quick check17:52
- 10Checklist and next lesson18:17
Preview transcript
1027 wordsThis is the text of the open part of this lesson. The full transcript comes with the course, along with the job site materials.
Intro
0:00Trunk cable laid along the rail, the last micro clicked in, and the end of the cable still open. What closes that end has a torque, written in the manufacturer's manual. Hi, I'm Sol. This is lesson three point one, the first one on the AC side. And I'm Helios. I brought the end of the cable, and a nut somebody tightened by feel. The topic is the DS3 trunk cable, its connectors, and the end cap that closes it. With the U.S. manual, the quick guide, and the U.S. accessories summary on screen. By the end of this lesson, you'll plug the micro into the trunk and close the end the way the manual says. And I want to know which cable goes up on the roof. There's more than one kind in the shop. There is, and APsystems publishes how to tell them apart. Start at the beginning. What's that thick cable running across the whole roof for? Here's the route: the trunk cable, the colors, single-phase or three-phase, and the click with its tool. Then the end cap, closing or extending the line, the cable's path, and a mistake that starts in the shop.
What the trunk cable does
1:23Chapter one. The user manual, page nine: additional accessories supplied by APsystems. The AC Y3 bus cable, its end cap, its Y-CONN cap, the unlock tool, the ECU, and AC connectors, male and female. Bus cable? On the job I call it the trunk cable. Same part. The manual says bus cable, and in step five it calls the connector the trunk cable connector. Page eleven, step two: the Y3 AC bus cable distribution. One end of the bus cable goes to the junction box connected to the grid. Three conductors, no neutral: L one, L two, and the PE, the ground that grounds the micros. The U.S. accessories summary draws the whole line: the DS3 series wiring diagram, page three. At the free end, the bus cable end cap, or an ACB three connector with one more micro. In the middle, the bus cable. And the unlock tool, the CONN cap for an unused drop, and the DC caps. All in one drawing. And how do the micros sit along that cable? In parallel. The U.S. table says it, page five: for grid connection of multiple microinverters in parallel. So the trunk is one line for the whole row, with many micros on it. And the table marks the bus cable mandatory, in two versions: twelve AWG, two meters, and ten AWG, two point four meters. Ordered by part number, together with the micros. It never comes in the micro's box. The drawing of the twelve AWG cable, page eighteen. Cable marking: type TC-ER, three conductors, ninety degrees Celsius, wet or dry, six hundred volts. Working current rating of the cable: twenty-eight amps. Waterproof rating IP67. And how many connectors does it carry? The drawing describes a series of up to a hundred fifty connectors, one every two thousand one hundred fifty millimeters, about seven point one feet. The ten AWG cable, page nineteen: the same type TC-ER, with thirty-five amps of working current. Up to sixty connectors, one every two thousand four hundred millimeters, about seven point nine feet. Two spacings. So the layout of the micros on the rail follows the cable, planned before the job. And the table's note says the cable's diameter and length can be customized to the customer's needs. One more number for the trunk: in the U.S. limited warranty, the bus cable is an accessory, with two years. Two years for the cable. The micro's twenty-five years come with the ECU condition of lesson zero point one. And how many micros fit on each one? That's next lesson's math. For today, one idea: the branch takes the lowest of three: the datasheet, the code math, and the trunk cable's own rating. And the trunk is the manufacturer's listed cable. The run from the junction box to the panel is yours, sized by the code.
The colors and the connector face
5:00Chapter two. Same page eleven, step two, item b: the conductors of the AC bus. L one, black. L two, red. PE, green. Two lines and the ground. No neutral here. And the warning below: wiring color codes may vary with local regulations, so make sure every wire of the installation matches before connecting. And if something's crossed? Incorrect cabling can irreparably damage the microinverters, and that damage is not covered by the warranty. The quick guide prints two standards in step two. The European one: brown, blue, and yellow-green. And the American one. On a U.S. job, the American standard: L one black, L two red, PE green. And the local rule is the NEC. Lesson one point three showed it: green is for ground, and for nothing else. And the house rule: from the junction box to the panel, the line conductors are never white, gray, or green. And on the connector itself, how do I know which pin is which? Manual, page thirteen, the AC connector interface. Left to right: L one, PE, L two. The ground in the middle. The quick guide shows two options: L, PE, N, or L one, PE, L two. For the DS3 in the U.S., L one, PE, L two. And the cable drawing's wiring note matches: black L one, red L two, green PE. The step eight drawing shows the other end: black and red on a two-pole breaker, green on the ground bar. The manual says bi-polar circuit breakers. In the field, that's a two-pole breaker, and its rating comes from the next lesson.
Single-phase or three-phase
7:05Chapter three. APsystems publishes a sheet comparing the single-phase Y bus cable with the three-phase one. Three differences: the color of the package label, the printing on the cable, and the colors of the cores. Why would anybody mix them up? Because both exist, and the sheet was written to tell them apart. The three-phase one is for the QT2 and the QT2D. One: the package label. Single-phase, black characters on a white background. Three-phase, black on blue. Two: the printing on the cable. On the single-phase cable, the word three-phase isn't printed.
Job site materials in every lesson, questions inside the video, spaced review, a final exam and a certificate of completion with a public verification code. 7 days to cancel, with a full refund.